Laser-integrated real-time OCT in anterior segment procedures
- PMID: 34393183
- DOI: 10.1097/j.jcrs.0000000000000773
Laser-integrated real-time OCT in anterior segment procedures
Abstract
Intraoperative optical coherence tomography (OCT) was so far only available as a microscope-integrated or handheld device. Recently, this technology has been integrated into a femtosecond (FS) laser. This pilot study analyzed the potential of intraoperative imaging using OCT during FS-assisted procedures of the anterior eye segment. Therefore, intraoperatively acquired videos using FS-integrated intraoperative OCT (laser-integrated [LI] OCT) in 14 patients (Victus, Bausch & Lomb) were analyzed in different surgical procedures. The results showed that all surgical steps could be successfully visualized by LI-OCT. LI-OCT added important information regarding the depth and location of the incisions and dissection planes. Moreover, dynamic processes could be observed in real-time. LI-OCT represents a new imaging technology that makes it possible to visualize intraoperative steps during FS-assisted surgery. In the future, automatic image analysis based on artificial intelligence could be helpful to detect complications at an early stage and to automatically stop the laser process in relevant constellations.
Copyright © 2021 Published by Wolters Kluwer on behalf of ASCRS and ESCRS.
Similar articles
-
[Intraoperative optical coherence tomography in corneal and glaucoma surgical procedures].Ophthalmologe. 2016 Aug;113(8):646-50. doi: 10.1007/s00347-016-0320-y. Ophthalmologe. 2016. PMID: 27436117 Review. German.
-
Preclinical evaluation and intraoperative human retinal imaging with a high-resolution microscope-integrated spectral domain optical coherence tomography device.Retina. 2013 Jul-Aug;33(7):1328-37. doi: 10.1097/IAE.0b013e3182831293. Retina. 2013. PMID: 23538579 Free PMC article.
-
Microscope Integrated Intraoperative Spectral Domain Optical Coherence Tomography for Cataract Surgery: Uses and Applications.Curr Eye Res. 2016 May;41(5):643-52. doi: 10.3109/02713683.2015.1050742. Epub 2015 Aug 3. Curr Eye Res. 2016. PMID: 26237163
-
Femtosecond laser-integrated anterior segment optical coherence tomography to detect preexisting posterior capsular dehiscence and increase safety in posterior polar cataracts.J Cataract Refract Surg. 2020 Feb;46(2):235-240. doi: 10.1097/j.jcrs.0000000000000048. J Cataract Refract Surg. 2020. PMID: 32126037
-
[Optical coherence tomography: from retina imaging to intraoperative use - a review].Klin Monbl Augenheilkd. 2009 Dec;226(12):958-64. doi: 10.1055/s-0028-1109939. Epub 2009 Dec 15. Klin Monbl Augenheilkd. 2009. PMID: 20108189 Review. German.
References
-
- Geerling G, Müller M, Winter C, Hoerauf H, Oelckers S, Laqua H, Birngruber R. Intraoperative 2-dimensional optical coherence tomography as a new tool for anterior segment surgery. Arch Ophthalmol 2005;123:253–257
-
- Ehlers JP, Dupps WJ, Kaiser PK, Goshe J, Singh RP, Petkovsek D, Srivastava SK. The Prospective Intraoperative and Perioperative Ophthalmic ImagiNg with Optical CoherEncE TomogRaphy (PIONEER) study: 2-year results. Am J Ophthalmol 2014;158:999–1007
-
- Ehlers JP, Kaiser PK, Srivastava SK. Intraoperative optical coherence tomography using the RESCAN 700: preliminary results from the DISCOVER study. Br J Ophthalmol 2014;98:1329–1332
-
- Siebelmann S, Steven P, Cursiefen C. Intraoperative optical coherence tomography: ocular surgery on a higher level or just nice pictures? JAMA Ophthalmol 2015;133:1133–1134
-
- Kucumen RB, Gorgun E, Yenerel NM, Utine CA. Intraoperative use of AS-OCT during intrastromal corneal ring segment implantation. Ophthalmic Surg Lasers Imaging 2012;43:S109–S116
MeSH terms
LinkOut - more resources
Full Text Sources