Optical measurement of the axial eye length by laser Doppler interferometry
- PMID: 2001935
Optical measurement of the axial eye length by laser Doppler interferometry
Abstract
A new technique has been developed to determine the axial length of the human eye in vivo. Based on laser interferometry in conjunction with the Doppler technique, it uses partially coherent light. This new technique complies with laser safety regulations. High accuracy is achieved, the optical length (OL) can be determined within +/- 30 microns, and the reproducibility of the geometric eye length is greater than +/- 25 microns. Possible errors are discussed. First comparisons with the ultrasound technique yield good agreement for emmetropic subjects and for subjects with a myopia of up to 10 diopters. The advantages of the laser doppler interferometry (LDI) technique are high accuracy, high transversal resolution, and more comfort for the patient (it is a noncontact method; no anesthesia is needed). Possible future applications of LDI, like measurements of fundus profiles and of retinal thickness, are mentioned.
Similar articles
-
Measurement of corneal thickness by laser Doppler interferometry.Invest Ophthalmol Vis Sci. 1992 Jan;33(1):98-103. Invest Ophthalmol Vis Sci. 1992. PMID: 1730551
-
[Laser optic measurements of the axial length of the eye].Fortschr Ophthalmol. 1989;86(2):159-61. Fortschr Ophthalmol. 1989. PMID: 2737574 German.
-
Measurement of the axial length of cataract eyes by laser Doppler interferometry.Invest Ophthalmol Vis Sci. 1993 May;34(6):1886-93. Invest Ophthalmol Vis Sci. 1993. PMID: 8491541
-
Implantable hearing device performance measured by laser Doppler interferometry.Ear Nose Throat J. 1997 May;76(5):297-9, 302, 305-9. Ear Nose Throat J. 1997. PMID: 9170711 Review.
-
Peripheral eye length measurement techniques: a review.Clin Exp Optom. 2020 Mar;103(2):138-147. doi: 10.1111/cxo.12892. Epub 2019 Mar 20. Clin Exp Optom. 2020. PMID: 30895670 Review.
Cited by
-
Tomographic imaging via spectral encoding of spatial frequency.Opt Express. 2013 Mar 25;21(6):7488-504. doi: 10.1364/OE.21.007488. Opt Express. 2013. PMID: 23546131 Free PMC article.
-
Coherence revival multiplexed, buffered swept source optical coherence tomography: 400 kHz imaging with a 100 kHz source.Opt Lett. 2014 Jul 1;39(13):3740-3. doi: 10.1364/OL.39.003740. Opt Lett. 2014. PMID: 24978725 Free PMC article.
-
Quantification of attenuation and speckle features from endoscopic OCT images for the diagnosis of human brain glioma.Sci Rep. 2024 May 10;14(1):10722. doi: 10.1038/s41598-024-61292-z. Sci Rep. 2024. PMID: 38729956 Free PMC article.
-
Ultrahigh Resolution Polarization Sensitive Optical Coherence Tomography of the Human Cornea with Conical Scanning Pattern and Variable Dispersion Compensation.Appl Sci (Basel). 2019 Oct;9(20):4245. doi: 10.3390/app9204245. Epub 2019 Oct 11. Appl Sci (Basel). 2019. PMID: 31915537 Free PMC article.
-
Qualitative and quantitative evaluation of in vivo SD-OCT measurement of rat brain.Biomed Opt Express. 2017 Jan 5;8(2):593-607. doi: 10.1364/BOE.8.000593. eCollection 2017 Feb 1. Biomed Opt Express. 2017. PMID: 28270970 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical