Boston keratoprosthesis outcomes and complications
- PMID: 19724214
- DOI: 10.1097/ICO.0b013e3181a186dc
Boston keratoprosthesis outcomes and complications
Abstract
Purpose: To evaluate the outcomes of the Boston Keratoprosthesis (KPro) at our institution.
Methods: A computerized database retrospectively identified all patients who received a Boston KPro from August 2005 to October 2007.
Results: There were 37 patients, 24 (65%) were male. Mean age was 66.3 years (median 69 years, range: 24-93 years; SD = 18.1 years). Mean follow-up was 16 months (range: 6-28 months; SD = 6.0 months). There were 36 type 1 (97%) and 1 type 2 (3%) KPros. The primary indication was failed penetrating keratoplasty in 29 patients (78%)-22 (59%) from multiple failures. Preoperative comorbidities included glaucoma [27 patients (73%)] and limbal stem cell deficiency [13 patients (35%)]. No intraoperative complications occurred. Postoperative complications included retroprosthetic membrane [24 patients (65%)], increased intraocular pressure [14 patients (38%)], glaucoma progression [5 patients (13.5%)], and endophthalmitis [4 patients (11%)-3 who discontinued prophylactic antibiotics secondary to compliance]. Thirty-six KPros (97%) were retained-1 type 2 KPro (3%) in a patient with ocular cicatricial pemphigoid extruded and was replaced. Mean best-corrected visual acuities were counting fingers preoperatively (range: light perception to 20/100) and 20/90 at last follow-up (range: light perception to 20/25). At last follow-up, 31 patients (84%) improved 2 lines or greater-3 patients (8%) had worse vision.
Conclusions: Retention rates were excellent, and best-corrected visual acuities improved in the vast majority of patients. Complications can occur and require frequent follow-up to monitor and treat glaucoma progression, endophthalmitis, and inflammation. Patient compliance is of paramount importance. Despite the potential complications, the Boston KPro provides visual improvement in patients with an otherwise poor prognosis.
Similar articles
-
Glaucoma associated with Boston type I keratoprosthesis.Cornea. 2012 Feb;31(2):134-9. doi: 10.1097/ICO.0b013e31820f7a32. Cornea. 2012. PMID: 22134402 Free PMC article.
-
Long-term visual outcomes of the Boston type I keratoprosthesis in Canada.Br J Ophthalmol. 2020 Nov;104(11):1601-1607. doi: 10.1136/bjophthalmol-2019-315345. Epub 2020 Feb 17. Br J Ophthalmol. 2020. PMID: 32066560
-
Longer-term vision outcomes and complications with the Boston type 1 keratoprosthesis at the University of California, Davis.Ophthalmology. 2011 Aug;118(8):1543-50. doi: 10.1016/j.ophtha.2010.12.032. Epub 2011 Mar 12. Ophthalmology. 2011. PMID: 21397948
-
Short-term Interim Results of Clinical Outcomes and Complications After Implantation of Boston Keratoprosthesis in Japanese Patients.Cornea. 2020 Nov;39 Suppl 1:S28-S33. doi: 10.1097/ICO.0000000000002453. Cornea. 2020. PMID: 32925428 Review.
-
Boston Type 1 Keratoprosthesis versus Repeat Donor Keratoplasty for Corneal Graft Failure: A Systematic Review and Meta-analysis.Ophthalmology. 2016 Jan;123(1):165-77. doi: 10.1016/j.ophtha.2015.09.028. Epub 2015 Nov 4. Ophthalmology. 2016. PMID: 26545318 Review.
Cited by
-
Boston type 1 keratoprosthesis: the New York Eye and Ear experience.Eye (Lond). 2012 Mar;26(3):418-25. doi: 10.1038/eye.2011.325. Epub 2011 Dec 16. Eye (Lond). 2012. PMID: 22173079 Free PMC article.
-
Outcomes of the Boston keratoprosthesis in jordan.Middle East Afr J Ophthalmol. 2012 Jan;19(1):97-100. doi: 10.4103/0974-9233.92123. Middle East Afr J Ophthalmol. 2012. PMID: 22346122 Free PMC article.
-
Biocompatibility of poly(ethylene glycol) and poly(acrylic acid) interpenetrating network hydrogel by intrastromal implantation in rabbit cornea.J Biomed Mater Res A. 2015 Oct;103(10):3157-65. doi: 10.1002/jbm.a.35453. Epub 2015 Mar 27. J Biomed Mater Res A. 2015. PMID: 25778285 Free PMC article.
-
Three-Dimensional Optical Coherence Tomography Imaging For Glaucoma Associated With Boston Keratoprosthesis Type I and II.J Glaucoma. 2019 Aug;28(8):718-726. doi: 10.1097/IJG.0000000000001280. J Glaucoma. 2019. PMID: 31169563 Free PMC article.
-
Artificial corneas versus donor corneas for repeat corneal transplants.Cochrane Database Syst Rev. 2020 May 13;5(5):CD009561. doi: 10.1002/14651858.CD009561.pub3. Cochrane Database Syst Rev. 2020. PMID: 32408386 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical