Review
. 2016 Aug;113(8):646-50.
doi: 10.1007/s00347-016-0320-y.

[Intraoperative optical coherence tomography in corneal and glaucoma surgical procedures]

[Article in German]
Affiliations
Review

[Intraoperative optical coherence tomography in corneal and glaucoma surgical procedures]

[Article in German]
S Siebelmann et al. Ophthalmologe. 2016 Aug.

Abstract

Background: Optical coherence tomography (OCT) is the clinical gold standard for anterior and posterior segment imaging. Since OCT devices have been integrated into surgical microscopes, this technique is also available intraoperatively in anterior segment surgery. OCT is well established in imaging very thin or transparent structures as they appear in corneal or glaucoma surgery. Therefore, intraoperative OCT can deliver important information for the surgeon which is superior to the normal surgical microscope.

Objectives: In the present work, an overview about the opportunities of intraoperative OCT in cornea and glaucoma surgery are presented.

Material and methods: The recent literature (PubMed) and our own experience at the Center for Ophthalmology, University Hospital of Cologne are analysed.

Results: Intraoperative OCT enables real-time imaging during corneal and glaucoma surgery. Several clinical studies exist, indicating its benefit, e. g. in DMEK, DALK, DSAEK, Boston Keratoprosthesis, canaloplasty or trabectome surgery. Several structures, not visible in the surgical microscope, can be visualized using intraoperative OCT.

Conclusions: As a real-time and high-resolution imaging device, intraoperative online OCT delivers additional information in glaucoma and corneal surgery, compared to the normal operating microscope. Nonetheless one of the main problems is the shadowing produced by surgical instruments. Today the main limitation is the lack of randomized-controlled clinical trials, evaluating the benefit of microscope-integrated intraoperative OCT, compared to the microscope.

Keywords: Canaloplasty; Deep anterior lamellar keratoplasty; Descemet membrane endothelial keratoplasty; Descemet’s stripping automated endothelial keratoplasty; Surgical microscope.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Eye (Lond). 2003 Apr;17 (3):340-5 - PubMed
    1. Cornea. 2015 Dec;34(12 ):1606-10 - PubMed
    1. JAMA Ophthalmol. 2015 Oct;133(10):1133-4 - PubMed
    1. Am J Ophthalmol. 1996 Jun;121(6):718-20 - PubMed
    1. Am J Ophthalmol. 2015 Sep;160(3):430-7 - PubMed

MeSH terms

LinkOut - more resources