R32 VERSATI Brief Introduction

VERSATI III is a multifunctional air-to-water heat pump that provides heating, domestic hot water, and cooling, utilizing eco-friendly R32 refrigerant for improved efficiency and lower CO2 emissions. Key features include advanced inverter technology, high-efficiency components, and various operational modes for optimal performance. The product comparison highlights enhanced user-friendly controls and the option for onsite installation of an auxiliary electric heater.

Uploaded by

ioanavasilem79
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
87 views44 pages

R32 VERSATI Brief Introduction

VERSATI III is a multifunctional air-to-water heat pump that provides heating, domestic hot water, and cooling, utilizing eco-friendly R32 refrigerant for improved efficiency and lower CO2 emissions. Key features include advanced inverter technology, high-efficiency components, and various operational modes for optimal performance. The product comparison highlights enhanced user-friendly controls and the option for onsite installation of an auxiliary electric heater.

Uploaded by

ioanavasilem79
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 44

VERSATI Ⅲ

Brief Introduction
CONTENTS
1 Product Introduction

2 Key Components

3 Product Features

4 Product Comparison
1 Product Introduction
VERSATI, a DC inverter multifunctional air to water heat pump adopting
advanced heat pump technology, absorbs natural heat from the ambient air
for room heating. It not only satisfies room heating requirements but also
supplies domestic hot water. Besides, VERSATI can also provide you a
cool air in hot summer.

VERSATI adopts R32(ODP=0,GWP=675), an eco-friendly refrigerant which


is harmless to the atmosphere. Moreover, with advanced heat pump
technology and powerful hardware, the efficiency of VERSATI has been
improved, resulting in much lower CO2 emission. It is a green product.
VERSATI Ⅲ

COP = 5.1

VERSATI Ⅱ+

COP = 4.6

VERSATI Ⅱ

COP = 4.5
AC Unit

GRS 16 Pd
GRS CC QQ 16 Pd //Nh
Nh GG --MM
Power supply
Power supply
M–380-415V/50Hz/3ph
M–380-415V/50Hz/3ph
K–3220-240V/50Hz/1ph
K–3220-240V/50Hz/1ph
Design sequence:
Design sequence:
Sequencing by A,B,C…
Sequencing by A,B,C…
Refrigerant type: Nh: R32
Refrigerant type:Na:
Nh:R410A
R32
Na: R410A

DC inverter
DC inverter

Nominal heating capacity (kW)


Nominal heating capacity (kW)

Multi heat pump


Multi heat pump

Heating mode: Circulating


Heating mode: Circulating

GREE ATW
GREE ATW
JJ
SX
SX VV DD 200 C
200 LL C 2 // AA -- MM
2
Power supply
Power supply
M–380-415V/50Hz/3ph
M–380-415V/50Hz/3ph
Design sequence:
Design sequence:
Sequencing by A,B,C…
Sequencing by A,B,C…
J2 = Dual Coiled Pipe
J J2 = DualCoiled
= Single CoiledPipe
Pipe
J = Single Coiled Pipe
Pressure-resistant
Pressure-resistant

Stand type
Stand type

Tank Volume
Tank Volume

Electric heater
Electric heater

Heat Pump Water Tank for


HeatUnits
GMV Pump Water Tank for
GMV Units
Water Tank
Water Tank
4/6/8/kW 10/12/14/16kW
A7W35 A35W18
Model Power supply
Capacity COP Capacity EER
GRS-CQ4.0Pd/NhG-K 220~240V/1ph/50Hz 4.0kW 5.10 3.8kW 4.80

GRS-CQ6.0Pd/NhG-K 220~240V/1ph/50Hz 6.0kW 4.90 5.8kW 4.40

GRS-CQ8.0Pd/NhG-K 220~240V/1ph/50Hz 7.5kW 4.60 6.8kW 4.00

GRS-CQ10Pd/NhG-K 220~240V/1ph/50Hz 10kW 4.65 8.8kW 4.40

GRS-CQ12Pd/NhG-K 220~240V/1ph/50Hz 12kW 4.50 11.0kW 4.20

GRS-CQ14Pd/NhG-K 220~240V/1ph/50Hz 14kW 4.30 12.5kW 4.00

GRS-CQ16Pd/NhG-K 220~240V/1ph/50Hz 15.5kW 4.20 14.5kW 3.70


10/12/14/16kW

A7W35 A35W18
Model Power supply
Capacity COP Capacity EER
GRS-CQ10Pd/NhG-K 220~240V/1ph/50Hz 10kW 4.60 8.8kW 4.50

GRS-CQ12Pd/NhG-K 220~240V/1ph/50Hz 12kW 4.40 11.0kW 4.35

GRS-CQ14Pd/NhG-K 220~240V/1ph/50Hz 14kW 4.20 12.8kW 4.00

GRS-CQ16Pd/NhG-K 220~240V/1ph/50Hz 15.5kW 4.10 14.5kW 3.65


Water Tank

Model Power supply Electric heater power Volume


SXVD200LCJ/A-K 220~240V/1ph/50Hz 3000W 200
SXVD200LCJ2/A-K 220~240V/1ph/50Hz 3000W 200

SXVD300LCJ/A-K 220~240V/1ph/50Hz 3000W 300

SXVD300LCJ2/A-K 220~240V/1ph/50Hz 3000W 300


SXVD200LCJ/A-M 380~415V/3ph/50Hz 3000W 200
SXVD200LCJ2/A-M 380~415V/3ph/50Hz 3000W 200
SXVD300LCJ/A-M 380~415V/3ph/50Hz 3000W 300
SXVD300LCJ2/A-M 380~415V/3ph/50Hz 3000W 300

200/300
2 Key Components
4/6/8kW 10/12/14/16kW
Current Current date
mode

General
setting

ON/OFF

Function Parameter Commissionin


setting viewing g parameters

Parameter
setting
Hign Efficient Axial Fan
Efficient axial fan with its streamline design and huge air flow volume, offers
powerful cooling capacity and ensures the stability and reliability of system.

BLDC Fan Motor

Stepless adjustment of DC fan motor ensures higher air flow volume and lower
power consumption.
Twin Rotary DC Inverter Compressor for VERSATI Ⅲ

Compared with traditional compressor, DC inverter compressor has the advantages of high
performance and high efficiency.

High efficiency brushless DC inverter motor

High efficiency pump with powerful capacity

4 pole winding design with lanthanon

 DC inverter system: The inverter technology with high-power and high energy efficiency
not only creates comfortable living circumstance, but also saves energy.
 Traditional system: ON and OFF frequency cause temperature fluctuation.
Low-Temp Hi-heat Dual-stage Compressor For VERSATI Ⅱ+
and VERSATI Ⅲ
High Efficiency Fin Tube

Normal Flat Fin Louver Fin


with Blue Coated Inner Groove Copper Tube

 Compared with the common fin, the heat exchange


efficiency of the louver fin is increased by 5%.
 Special thickened inside-thread copper pipe
enhances the heat exchange performance by over 8%.
 Highly anti-corrosion blue hydrophilic coated
aluminum fin has longer lifespan than common blue fin.
Gold fin is optional.
High Efficiency Plate Heat Exchanger

Water

Refrigerant

Danfoss PHE Alfa Laval PHE


(Condenser)
Schematic
(Economizer)

 Compact structure, smaller volume and lower pressure drop.


 Highly anti-corrosion performance.
 High thermal efficiency.
 Lower Fouling factor.
 Easy cleanout and maintenance.
Inverter Water Pump For VERSATI Ⅱ and Ⅱ+ and VERSATI Ⅲ
For E & G series WP

The A-class high-efficiency inverter water pump which complies with the
European Erp directive, can control the running frequency based on the
actual load. Therefore, it can enhance the operation effcieicy and control
the water temperature more accurately.
Schematic

 Balance the water flow and pressure in system.


 Keep the system pressure stability, avoid negative pressure produced in system.
 Ensure a reliable operation system.
•Single-coil Design
•Dual-coil Design
•Dual-temp Sensor Design
•Magnesium Stick
•Decentralized Water-inlet Design
Hot water outlet
Circulation water
outlet
Circulation water inlet
Magnesium stick
Temp Sensor 1

Circulation water
outlet
Temp Sensor 2
Circulation water inlet
Cool water inlet
Dual-coil Design

Upper Coil
(Design for other heat Solar
source) Panel

Lower Coil
(Design for heat
pump)
Dual-Temp Sensor Design

ON and OFF control of the unit is realized by lower temperature


sensors, which renews water temperature in real time, thus ensuring
the perfect timing of startup.

Upper temperature sensor is used for Solar system or Other Thermal


system(e.g. Boiler).
Upper temp
Sensor

Lower temp
Sensor
Magnesium Stick
 Adopting bearing tank, the unit can replenish water when using water, ensure rapid
storage and continuous delivery.
 50mm thickness of thermal insulating layer.
 Magnesium stick protecting container contributes to lifespan.
 Stainless steel tank and coil will not affect the water quality.
Decentralized Water-inlet Design
 Water inlet pipe
Water is charged from the bottom and the water inlet pipe has equispaced water inlets,
which can reduce cold water shock and enhance the service life of the tank.
 Slowing-up clapboard
Solve the problem of low use rate of hot water resulted from mixture of cold water and hot
water in circulating water pump.

Cold water inlet pipe


with decentralized Slowing-up clapboard
water inlets
3 Product Features
Outdoor temp. User Side
temp.
Cooling 10~48℃ 7~25℃
Heating -25~35℃ 25~60℃
Water
-25~45℃ 40~80℃
heating
Outdoor temp. User Side
temp.
Cooling 10~48℃ 7~25℃
Heating -25~35℃ 25~60℃
Water
-25~45℃ 40~80℃
heating
In this mode, the heat pump and the electric heater of the water tank operate at the same
time to realize rapid heating.


If tank temp is 80 ℃, the highest temp of heat pump is 50 ℃. When unit start work, the water
heating will realized with heat pump before tank temp reaches 50 ℃; and then tank temp will
be heating from 50 ℃ to 80 ℃ by e-heater only.
× ×

 When there are some malfunction happened , customer can chose


emergency operation , under this condition , the unit will start the back-up
thermal or the auxiliary electric heater to realize heat and hot water .

NOTE: The emergency function only available when the back-up


thermal or the auxiliary electric heater is installed 。
When user is on a trip in winter, the unit can be set to operate
automatically so as to keep the room temperature between 10 and 15℃.
On the other hand, it can prevent the water system from freezing.

If outdoor unit has any malfunction and stop work, the back-up e-heaters
begin work; and when room temp or leaving water temp reaches the
default value, back-up e-heater stop work.
The mode is available for heating/cooling/heat + hot water/cool + hot
water. But ONLY control heating/cooling outlet temperature ,NOT for
water tank temperature.

If user choose the water temp as control , There are three kinds of situations:
 Outdoor temp ≧ Upper OT-Heat, The default target temp is keep Lower-WT-Heat.
 Outdoor temp ≦ Lower OT-Heat, the default target temp is keep Upper WT-Heat.
 Lower OT-Heat < Outdoor temp < Upper OT-Heat , the default target temp will have a
linear change as the outdoor temp.
In this mode, the water heating system can be disinfected. When starting
up disinfection function and setting corresponding time to meet the
requirement of disinfection mode, the function will start. After the setting
temp is reached, this mode will terminate.

In this mode, the water temp can be up to 70℃, and it can prevent the
growth of bacteria and ensure sanitary water, creating a wholesome life
experience for user.
3 options of control logic for backup thermal according to requirement can be chosen :
logic 1/ logic 2/ logic 3

Logic1 : backup heat source is just for heating ; Its setting water temperature equals
the whole unit setting temperature.
Logic2 : backup thermal source can be used for heating and hot water through the 3-
way valve , setting water temperature of backup heater should less than 60℃ ;
Logic3 : The unit sends signal to energize the backup thermal , but it will not control
3-way valve or 2-way valve which only can be controlled manually
There is no auxiliary built-in e-heater with the VERSATI Ⅲ 。 The
customer can install it onsite according the actual project situation .
Once e –heater installed, there are 2 logics can be chosen to control

Logic1 : Heat pump and e-heater will not be energized simultaneously.


Logic2 : Heat pump and e-heater can be energized simultaneously under
low temperature condition
4 Product Comparison
1345

1438

878
460 1200
900 1350
2

381
41
Compared with VERSATI Ⅱ& Ⅱ+ , the controller of VERSATI Ⅲ is much
humanization and much easier to handle, customer no need to look up the
user manual.
VERSATI Ⅲ has a much perfect e-heater control logic.

 Optional E-heater installed by field supply

There is no auxiliary built-in e-heater with the VERSATI Ⅲ 。 The customer can
install it onsite according the actual project situation , the control port for the relay of
e-heater is available with the unit
 E-heater in tank
Controlling port of Ac contactor for water tank e-heater is available on unit.